The best solution for remote adjustment of inaccessible air balancing dampers.
- Never any hard wiring or building power needed.
- Flexible and fast installation options.
- Precise damper adjustment.
- Exclusive Smart Phone Remote Control Option.
Why ZipSet?
- No more relying on cantankerous, field assembled, mech cables or worm-gear gadgets.
- The Battery Powered HHC, Hand Held Controller operates the damper actuator. Building power is never used.
- NO hard wiring is ever needed.
- Bluetooth/Smart Phone remote control option for long runs up to 150 ft.
- The ZS offers a complete line of single blade dampers. To save time and labor $, consider choosing the ZS dampers with the actuator pre-installed.
- Your dampers are already purchased or installed ? No problem. ZSA-1 actuators easily mount to most damper brands.
- Proven reliability. Since 2007, there are now thousands of ZipSet dampers installed in hundreds of projects.
With 100’s of Completed Projects . . . A Dozen Notables:
The ZipSet System has two essential components:
The first is the Hand Held Controller, ‘HHC-1 Series’ :
Model HHC-1
Local adjustment of the damper via its 4 ft. power cable.
The 9V battery powers the actuator. No building power or hard wiring is ever needed.
The second essential component is the damper actuator, Model ZSA-1:
- Precise CW or CCW control to set airflow.
- Auto-locks the blade in place when finished.
- Premounted on dampers furnished by ZipSet or easily mounts to most damper brands.
Who Cares and Why . . .
Architects & Interior Designers
- Eliminates Ceiling Access Doors.
- With the Remote Panel or the ‘Feed Thru’ Options, It’s Invisible.
Building Owners and Managers
- Very Economical Installed Cost.
- Easy Readjustment with Tenant Changes.
HVAC Design Engineers
- Simple and Reliable Design.
- This Proven System Really Works.
HVAC Contractors
- Installs in Minutes with 3 Options.
- No ‘Wagging’ the Labor Cost.
Air Balancing Contractors
- Local and Optional Wireless Remote Adjustments Are Quick and Accurate.
Connecting the HHC Series Controller to the ZSA-1 Actuator is easy with two options . . .
OPTION #2 – ‘FEED THRU’
- The ‘Feed Thru” option may be the right choice when running the power cable down the supply duct makes sense.
- Works well with ceiling and slot diffusers because it allows the damper to be back from the inlet to reduce air noise issues.
- Completely invisible when using the retainer clip. Feed Thru Photo
Miscellaneous Components . . .
Even a well designed HVAC system may perform poorly and waste energy if not properly balanced. The ZIPSET SYSTEM for adjusting inaccessible air balancing dampers, insures a quick, precise, and economical solution.